9 volt types with 6 and 7 cells are charging with 20mA; P1 must be adjusted so that the NiCd charger disconnects after 14 hours. Window inferior level is set at 1V below this value with P2. 5V battery type with 4 or 5 cells are charged at 55mA. Again, with P1 adjust the NiCd charger circuit so it disconnects after 14 hours. Window inferior level must be set at 0.8V below this value.
Circuit diagram:
Parts:
P1 = 50K
P2 = 50K
R1 = 820R
R2 = 820R
R3 = 1K
R4 = 10K
R5 = 10K
R6 = 100R
D1 = 4.7V Zener
D2 = 1N4001
D4 = 1N4148
D5 = B40C1500 Diode Bridge
C1 = 220uF - 25V
Q1 = BC547B
IC = 555
B1 = 9V Ni-Cad Battery
|
Subscribe now and get all Projects, Circuit Diagrams and EBooks right in your inbox absolutely free. Don't worry it takes only 20 seconds.
|
be a part of us join 5000+ subscribers
|




5 comments:
what is D3
3mm RED LED and 3mm GREEN LED.
Hi, what you mind when you say Window inferior level ? and how should I adjust P1 to disconnects after 14 hors? Thank´s
Pins 6 & 3 are swapped on the circuit. pin 3 is the output on the 555 IC. Pin 6 is an input
Please can you tell me what "Window inferior level" means, and what levels am I looking for. Also how do I adjust P1 to disconnect after 14 hrs?
Thanks
Alan
Post a Comment
Share with me whatever in your mind. Comment is welcomed to all.